Search results for " GTA"

showing 7 items of 7 documents

Preliminary magnetic resonance relaxometric analysis of Fricke gel dosimeters produced with polyvinyl alcohol and glutaraldehyde

2017

This work describes the preliminary analysis of Fricke gels dosimeters characterized by a new formulation making use of a matrix of polyvinyl alcohol cross-linked by adding glutaraldehyde and analyzed by means of nuclear magnetic resonance relaxometry. In previous optical studies, these gels have shown promising dosimetric features in terms of photon sensitivity and low diffusion of ferric ions produced after irradiation. In this work, we used a portable nuclear magnetic resonance relaxometer to measure the relaxation times (which are important for dosimetric applications) of these gel materials. For this purpose, we performed a study for optimizing the acquisition parameters with a nuclear…

gelMaterials science02 engineering and technology01 natural sciencesPolyvinyl alcoholchemistry.chemical_compound0103 physical sciencesmedicinelcsh:Nuclear and particle physics. Atomic energy. RadioactivityFricke gelSafety Risk Reliability and QualityradiotherapySettore CHIM/02 - Chimica FisicaDosimetermedicine.diagnostic_testdosimetry010308 nuclear & particles physicsSettore FIS/01 - Fisica SperimentaleMagnetic resonance imaging021001 nanoscience & nanotechnologySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Dosimetry Gel NMR PVA GTA radiotherapynuclear magnetic resonancepolyvinyl alcoholNuclear Energy and Engineeringchemistryglutaraldehydelcsh:QC770-798Glutaraldehyde0210 nano-technologySettore MED/36 - Diagnostica Per Immagini E RadioterapiaDosimetry; Gel; Glutaraldehyde; Nuclear magnetic resonance; Polyvinyl alcohol; RadiotherapyNuclear chemistryNuclear Technology and Radiation Protection
researchProduct

Diffusion and sensitivity characteristics of a chemically cross-linked PVA-Fricke gel dosimeter

2016

Introduction: Current radiotherapy techniques implement treatment plans based on volumetric distributions of dose with complex shapes and sharp gradients. The agreement between these plans and the dose that is truly delivered is very challenging to verify. Thus, there is the need for a dosimetric system that is truly three dimensional, sensitive to radiation in each point and tissue equivalent. In this framework, great interest is encountered by radio-chromic gel dosimeters. In order to address the limitations of gels based on natural matrices, some investigators have proposed dosimeters based on poly vinyl alcohol (PVA) made by freezing-thawing cycles. Even though these gels have a low dif…

Fricke gel dosimetrey agarose PVA GTASettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

GEL DOSIMETERS FOR RADIOTHERAPY APPLICATIONS: RESULTS OF A “RESEARCH PROJECT OF NATIONAL INTEREST” (PRIN)

2016

Introduction: Gel dosimeters for three-dimensional mapping of radiotherapy doses were introduced at Yale University in the mid-1980’s. Soon after, research and development in this field also started in Italy. Early work was done at the Istituto Superiore di Sanità and at the Universities of Pisa and Milan. Several institutes now collaborate on this topic with the goal of developing new formulations of hydrogel matrices with improved characteristics of stability, sensitivity and spatial resolution compared to those of earlier Fricke-gel and polymer-gel systems. Materials and methods: Contrary to earlier gels based on natural gelling agents, such as porcine skin gelatin and/or agarose, which …

Engineeringmedicine.medical_specialtyNational interestbusiness.industrySettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleBiophysicsGeneral Physics and AstronomySettore ING-IND/34 - Bioingegneria IndustrialeGeneral MedicineGel Dosimetry PVA GTA Agarose Gelatine MRI NMR Fricke gelSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)medicineRadiology Nuclear Medicine and imagingMedical physicsbusinessTelecommunicationsSettore CHIM/02 - Chimica Fisica
researchProduct

PVA gel dosimeters for radiotherapy applications,

2015

Gel dosimeters for three-dimensional mapping of radiotherapy doses were introduced at Yale University in the mid-1980’s. Soon after, research and development in this field also started in Italy. Early work was done at the Istituto Superiore di Sanità, and at the Universities of Pisa and Milan. Several institutes now collaborate on this topic with the goal of developing new formulations of hydrogel matrices with improved characteristics of stability, sensitivity and spatial resolution compared to those of earlier Fricke-gel and polymer-gel systems. Contrary to earlier gels based on natural gelling agents, such as porcine skin gelatin and/or agarose, which suffer from limited batch -to-batch …

Settore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleDosimetry gel fricke nmr mri PVA agarose GTASettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Modeling of Melt Flow and Heat Transfer in Stationary Gas Tungsten Arc Welding with Vertical and Tilted Torches

2021

A 3D numerical simulation was conducted to study the transient development of temperature distribution in stationary gas tungsten arc welding with filler wire. Heat transfer to the filler wire and the workpiece was investigated with vertical (90°) and titled (70°) torches. Heat flux, current flux, and gas drag force were calculated from the steady-state simulation of the arc. The temperature in the filler wire was determined at three different time intervals: 0.12 s, 0.24 s, and 0.36 s. The filler wire was assumed not to deform during this short time, and was therefore simulated as solid. The temperature in the workpiece was calculated at the same intervals using heat flux, current flux, ga…

ConvectionTechnologyheat transfer to the filler wireMaterials scienceBuoyancytransient heat transfer in GTAWengineering.materialArticlelaw.inventionlawtilted torchGeneral Materials ScienceComposite materialMicroscopyQC120-168.85GTAW with filler wireMarangoni effectTorchGas tungsten arc weldingTQH201-278.5melt flow in weld poolgas tungsten arc weldingEngineering (General). Civil engineering (General)TK1-9971Volume (thermodynamics)Heat fluxDescriptive and experimental mechanicsHeat transferengineeringElectrical engineering. Electronics. Nuclear engineeringTA1-2040Materials
researchProduct

Analysis of response of PVA-GTA Fricke gel dosimeters through magnetic resonance imaging.

2017

The experimental activities here reported are focused on the analysis of the clinical applications of Fricke gel dosimeters produced with a matrix of Polyvinyl alcohol (PVA) cross-linked by adding glutaraldehyde (GTA). The analyses were performed by means of a 1.5 T clinical magnetic resonance imaging (MRI) scanner. The sensitivity of these dosimetric gels to clinical photon beams as well as the signal stability were suitably investigated. Furthermore, the effect of the xylenol orange on the MRI signal was analyzed. The results obtained show that these PVA-GTA gel dosimeters show good dosimetric features for possible future use for 3D dose mapping in clinical applications.

Settore FIS/01 - Fisica SperimentaleGel dosimetry PVA GTA 3D dose MRI LINACSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

PVA-GTA Fricke gel dosimeters exposed to clinical photons beams: Nuclear Magnetic Resonance Relaxometry and Imaging

2016

Fricke Gel (FXGs) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. The application of Fricke gels for ionizing radiation dosimetry is continuously increasing worldwide due to their many favorable properties. However, one of their shortcomings is that ferrous and ferric ions diffuse in the gel matrix. To maintain the spatial integrity of the dose distribution, Fricke gels must be undergoing measurement within a few hours of their irradiation, so that ferric ions remain close to their point of production. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained (Schreiner, 2015). The gel matrix also contributes to the oxidati…

Gel Dosimeters NMR MRI PVA GTA 3D DoseSettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct